Air Monitoring Alarm Response

Air Monitoring Instrument
Thermo Scientific Model 5030 Sharp Monitor
Date and time of alarm
2/1/2025 12:00 AM
to
2/28/2025 12:00 PM
Air monitoring station
checked
M1
checked
M2
checked
M3
checked
M4
Alarm was caused by
checked
Loss of radio communication
checked
Loss of cellular connection
checked
Air unit malfunction
Name of technician who responded to the alarm
Scott Peterson
Was an email sent to the site technician?
checked
No
Were dredging or construction occurring during the alarm?
checked
No
Were corrective actions taken?
checked
No
Description of action taken
During the month of February, errors "air-units offline". Found antenna mounted to fence pole hose clamps were not tight. The wind was pushing the antenna out of alignment with base antenna. Tightened the hose clamps but may need to replace with heavy duty style clamp. New heavy-duty clamps are on order. Weather caused issues with radio communication. M3 vacuum pump needs replaced. Ordering is delay because of government spending freeze. M4 communication error is unknown at this time. Maybe a programming error in modem.